Skip to product information
1 of 1

VITAMIN STATION

VITAMIN STATION Rapid test Pregnancy blood test 1 pc

VITAMIN STATION Rapid test Pregnancy blood test 1 pc

Regular price $42.50
Regular price Sale price $42.50
Sale Sold out

Pregnancy blood tests are known to be more accurate than urine tests and detect pregnancy as early as a few days after fertilization . In addition, the amount of fluid ingested that may affect the urine test results (hCG dilution) has no effect on the blood test. Therefore, test yourself with the VITAMIN STATION rapid test in the comfort of your home and get up to 98% security . The accuracy of the test is really very important, because pregnancy necessarily requires preventive measures and lifestyle changes, such as quitting smoking or drinking alcohol, reducing or even stopping certain medications and foods. This test detects the presence of the hormone hCG (human chorionic gonadotropin) in a blood sample from a finger.

Main features:

  • home pregnancy blood test
  • easy and fast to use
  • result in as little as 5 minutes
  • reliability up to 98%
  • the package contains all the material needed to perform the test

Use

1. Wash your hands thoroughly. Use soap and warm water. Dry your hands with a clean towel.
2. Prepare the test and pipette. Remove them from the protective bag (tear off at the notch) and place them at your fingertips (you will need them later). Discard the small desiccant bag.
3. Prepare a lancet. Hold it gently without pressing the activation button. Turn the lancet cap a quarter turn until you feel it separate from the lancet. Then continue turning (2-3
turns). Do not pull, just turn, and discard the cap after removal.
4. Clean the tip of your index finger or middle finger with an alcohol swab. Massage the finger with light pressure towards its end to make the blood flow.
5. Press the lancet firmly against the side of the cleaned fingertip and press the activation button.
6. The tip automatically slides back into the device.
7. Support the formation of a drop of blood by massaging the fingertip.
8. Place the plastic pipette on the blood sample without squeezing the end of the pipette. The blood is drawn into the pipette thanks to the capillarity up to the comma marked on the pipette. If the blood does not reach the comma, massage the abdomen of the finger again to obtain the required amount of blood. Try to avoid air bubbles.
9. Apply the blood sample by squeezing the end of the pipette into the test window of the cartridge.
10. Wait 30-40 seconds for the blood to completely soak into the test window. Unscrew the blue cap of the buffer solution vial (leave the white cap firmly screwed on) and add the solution
as follows: hold the buffer solution bottle vertically and slowly add exactly 4
drops to the test window of the cartridge with an interval of 2-3 seconds between each drop.
11. Read the result between 5 and 10 minutes. Do not read the result after more than 10 minutes.

View full details